YUKON CHOICE PC
Product Details:
YUKON CHOICE PC Price And Quantity
- 1 INR/Unit
- 100 Unit
YUKON CHOICE PC Trade Information
- 100000 Unit Per Month
- 1-7 Days
Product Description
Yukon Choice PC is known as a Biodegradable Polymer Coronary Drug Eluting Stent. It is accessible with a well-studied and clinically proven immunosuppressant. The patented technology of this product allows it to work well with reservoirs. Yukon Choice PCallows for less systemic exposure and better endothelializationof drug. Its use can prevent the dual drug matrix break ups when a stent expansion is being on. This is a longest studied DES offered with safety and efficacy.
Yukon Choice PC – World’s Longest Studied Coronary Drug Eluting Stent
- Yukon Choice PC is a Biodegradable Polymer Coronary Drug Eluting Stent. The Drug is Sirolimus which is a well-studied and clinically proven immunosuppressant.
- The Stent platform is of Stainless Steel with Microporous Stent Surface. The patented technology of micro pores acts like reservoirs for delivering the drug to the targeted site. Micro pores use vander-wall forces for the controlled released of drug. Microporous surface also reduce the polymer load to 1/4th.
- The Dual drug matrix is coated on the Abluminal side which ensures better Endothelialization and less systemic exposure of the drug.
- Shellac Resin is the top coat of the stent for smooth surface which prevents dual drug matrix break ups during stent expansion.
- Yukon Choice PC is one of the longest studied DES with 10 years of data establishing its safety and efficacy published in Circulation
Product Matrix/ Ordering Information
Stent Diameter Ø (mm) | Stent length (mm) & Article number | |||||||
8 | 12 | 16 | 18 | 21 | 24 | 28 | 32 | |
Ø2.00 | YCPC2008 | YCPC2012 | YCPC2016 | YCPC2018 | YCPC2021 | YCPC2024 | YCPC2088 | YCPC2032 |
Ø2.25 | YCPC2208 | YCPC2212 | YCPC2216 | YCPC2218 | YCPC2221 | YCPC2224 | YCPC2228 | YCPC2232 |
Ø2.50 | YCPC2508 | YCPC2512 | YCPC2516 | YCPC2518 | YCPC2521 | YCPC2524 | YCPC2528 | YCPC2532 |
Stent Diameter Ø (mm) | Stent length (mm) & Article number | |||||||||
8 | 12 | 16 | 18 | 21 | 24 | 28 | 32 | 36 | 40 | |
Ø2.75 | YCPC2708 | YCPC2712 | YCPC2716 | YCPC2718 | YCPC2721 | YCPC2724 | YCPC2728 | YCPC2732 | YCPC2736 | YCPC2740 |
Ø3.00 | YCPC3008 | YCPC3012 | YCPC3016 | YCPC3018 | YCPC3021 | YCPC3024 | YCPC3028 | YCPC3032 | YCPC3036 | YCPC3040 |
Ø 3.50 | YCPC3508 | YCPC3512 | YCPC3516 | YCPC3518 | YCPC3521 | YCPC3524 | YCPC3528 | YCPC3532 | YCPC3536 | YCPC3540 |
Ø 4.00 | YCPC4008 | YCPC4012 | YCPC4016 | YCPC4018 | YCPC4020 | YCPC4024 | YCPC4028 | YCPC4032 | YCPC4036 | YCPC4040 |
Compliance Chart
Balloon Ø (mm) | Inflation pressure (bar/105 Pa | ||||||||||||||
| NP |
|
|
|
|
|
| RBP | |||||||
6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 | 17 | 18 | 19 | 20 | |
Ø 2.00 | 1.90 | 1.94 | 1.97 | 2.00 | 2.03 | 2.07 | 2.10 | 2.13 | 2.17 | 2.20 | 2.23 | 2.27 | 2.32 | 2.38 | 2.41 |
Ø 2.25 | 2.15 | 2.18 | 2.47 | 2.25 | 2.28 | 2.32 | 2.35 | 2.38 | 2.42 | 2.45 | 2.49 | 2.52 | 2.55 | 2.59 | 2.62 |
Ø 2.50 | 2.40 | 2.43 | 2.21 | 2.50 | 2.54 | 2.57 | 2.64 | 2.57 | 2.67 | 2.71 | 2.74 | 2.77 | 2.81 | 2.84 | 2.88 |
Ø 2.75 | 2.65 | 2.68 | 2.72 | 2.75 | 2.78 | 2.82 | 2.88 | 2.81 | 2.92 | 2.95 | 2.98 | 3.01 | 3.28 | 3.31 | 3.34 |
Ø 3.00 | 2.89 | 2.93 | 2.97 | 3.00 | 3.04 | 3.08 | 3.15 | 3.07 | 3.19 | 3.23 | 3.26 | 3.22 | 3.34 | 3.37 | 3.41 |
Ø 3.50 | 3.37 | 3.42 | 3.46 | 3.50 | 3.54 | 3.58 | 3.67 | 3.59 | 3.71 | 3.75 | 3.79 | 3.84 | 3.88 | 3.92 | 3.96 |
Ø 4.00 | 3.85 | 3.90 | 3.96 | 4.00 | 4.05 | 4.10 | 4.21 | 4.11 | 4.26 | 4.31 | 4.36 | 4.41 | 4.46 | 4.51 | 4.56 |
Technical Data
Crossing Profile (Ø 2.5 mm) | 0.035’’/0.89 mm |
Strut Thickness (Ø 2.5 mm) | 0.0034’’/87µm |
Metallic Surface Area | 16-18% |
No Foreshortening |
|
Balloon Marker Material | Platinum/ Iridium |
Entry Profile | 0.016’’/0.41 mm |
Proximal Shaft Diameter | 1.9 F |
Distal Shaft Diameter | 2.4 F |
Recommended Guide Wire | 0.014’’ |
Guiding Catheter | Min. 5 F |